Code | Description |
---|---|
G0 | General - Openings at one or both ends |
G1 | General - Passive vents at upper part of cargo space |
G2 | General - Openings at one or both ends + full openings on one or both sides |
G3 | General - Openings at one or both ends + partial openings on one or both sides |
V0 | Fantainer - Non-mechanical, vents at lower and upper parts of cargo space |
V2 | Fantainer - Mechanical ventilation system located internally |
V4 | Fantainer - Mechanical ventilation system located externally |
R0 | Integral Reefer - Mechanically refrigerated |
R1 | Integral Reefer - Mechanically refrigerated and heated |
R2 | Integral Reefer - Self-powered mechanically refrigerated |
R3 | Integral Reefer - Self-powered mechanically refrigerated and heated |
H0 | Refrigerated or heated with removable equipment located externally; heat transfer coefficient K=0.4W/M2.K |
H1 | Refrigerated or heated with removable equipment located internally |
H2 | Refrigerated or heated with removable equipment located externally; heat transfer coefficient K=0.7W/M2.K |
H5 | Insulated - Heat transfer coefficient K=0.4W/M2.K |
H6 | Insulated - Heat transfer coefficient K=0.7W/M2.K |
U0 | Open Top - Openings at one or both ends |
U1 | Open Top - Idem + removable top members in end frames |
U2 | Open Top - Openings at one or both ends + openings at one or both sides |
U3 | Open Top - Idem + removable top members in end frames |
U4 | Open Top - Openings at one or both ends + partial on one and full at other side |
U5 | Open Top - Complete, fixed side and end walls ( no doors ) |
T0 | Tank - Non dangerous liquids, minimum pressure 0.45 bar |
T1 | Tank - Non dangerous liquids, minimum pressure 1.50 bar |
T2 | Tank - Non dangerous liquids, minimum pressure 2.65 bar |
T3 | Tank - Dangerous liquids, minimum pressure 1.50 bar |
T4 | Tank - Dangerous liquids, minimum pressure 2.65 bar |
T5 | Tank - Dangerous liquids, minimum pressure 4.00 bar |
T6 | Tank - Dangerous liquids, minimum pressure 6.00 bar |
T7 | Tank - Gases, minimum pressure 9.10 bar |
T8 | Tank - Gases, minimum pressure 22.00 bar |
T9 | Tank - Gases, minimum pressure to be decided |
B0 | Bulk - Closed |
B1 | Bulk - Airtight |
B3 | Bulk - Horizontal discharge, test pressure 1.50 bar |
B4 | Bulk - Horizontal discharge, test pressure 2.65 bar |
B5 | Bulk - Tipping discharge, test pressure 1.50 bar |
B6 | Bulk - Tipping discharge, test pressure 2.65 bar |
P0 | Flat or Bolster - Plain platform |
P1 | Flat or Bolster - Two complete and fixed ends |
P2 | Flat or Bolster - Fixed posts, either free-standing or with removable top member |
P3 | Flat or Bolster - Folding complete end structure |
P4 | Flat or Bolster - Folding posts, either free-standing or with removable top member |
P5 | Flat or Bolster - Open top, open ends (skeletal) |
S0 | Livestock carrier |
S1 | Automobile carrier |
S2 | Live fish carrier |
Ülkemizde ve Dünyada konteyner terminalleri ve bu terminallerde uygulanan sistemler ile ilgili bilgi paylaşımının yapılacağı bir blog olması planlanmaktadır
KONTEYNER TİPLERİ VE KODLARI (CONTAINER TYPES AND CODES)
Kaydol:
Kayıt Yorumları (Atom)
Öne Çıkan Yayın
Terminal Operasyon Sistemi Nedir
Günümüzde küresel ticaretin belkemiği haline gelen konteyner taşımacılığı, deniz limanlarının verimli bir şekilde yönetilmesini gerektiren ...
-
Dünya ticaretinde önemli bir yer tutan konteyner taşımacılığında ana materyal olan ve dünyada binlerce bulunan bu konteyner numaraları nas...
-
Günümüzde konteyner taşımacılığının olağanüstü bir gelişme göstermesi ve gelecekte de bu gelişmenin devam edeceği göz önüne alındığında kont...
-
Code Description Code Description 20GP GENERAL PURPOSE CONT. 20G0 GENERAL PURPOSE CONT. 20GP GENERAL PURPOSE CONT. 20G1 GENERAL PURPOS...
Hiç yorum yok:
Yorum Gönder